VESDA ® LaserFocus
Home > VESDA ® > VESDA ® LaserFocus
Instant Recognition Display
The VESDA ® LaserFOCUS has been equipped with a clear, intuitive, circular smoke dial display that gives unprecedented event identification, allowing for immediate risk assessment and preventative action. Another example of why VESDA ® fire detection systems are regarded as the best in the world!.
This VESDA ® smoke detection unit, with its' well positioned LEDs and related icons, allow for instant identification of smoke growth and alarm conditions, even from a distance.
Features
- Out-of-the-Box Installation and Commissioning
- Ultrasonic Air. ow Sensing
- Laser-Based Absolute Smoke Detection
- Pre-engineered pipe network designs
- Programmable Alarm Thresholds
- Dual Stage Air Filtration
- Instant Recognition Display
- Instant Fault Finder
- AutoLearn Smoke
- AutoLearn Flow
- Field Service Access Door
- Multiple Event Logging in separate logs
- Event log up to 18000 events
- Of. ine/online con. guration capability
- Up to 250 m2 (2500 sq. ft.) coverage*
Immediate Analysis and Diagnostics with the Instant Fault Finder
To ensure ongoing system integrity, immediate assessment of the detectors condition is critical. By opening the service access door, the operator can activate the Instant Fault Finder feature - a smart diagnostic feature that converts the smoke dial into a fault indicator. It provides instant and meaningful information of the detectors status without the need for additional programming and evaluation tools. Now .re service and maintenance staff can be better informed before arriving onsite, reducing the time onsite, and saving on maintenance costs.
With the VESDA ® Pipe Network being such an integral part of any VESDA ® Air Sampling System, maintaining its integrity and reliability is critical in ensuring a consistently accurate level of detection performance. The VESDA ® LaserFOCUS utilises Ultrasonic Flow Sensing principles to assist in the measurement & monitoring of airflow. The VESDA ® LaserFOCUS detector immediately identifies and communicates any variances in the airflow rate.
Reliable Air Flow Monitoring using Ultrasonic Sensing
With the VESDA ® Pipe Network being such an integral part of any VESDA ® Air Sampling System, maintaining its integrity and reliability is critical in ensuring a consistently accurate level of detection performance. The VESDA ® LaserFOCUS utilises Ultrasonic Flow Sensing principles to assist in the measurement & monitoring of airflow. The VESDA ® LaserFOCUS detector immediately identifies and communicates any variances in the airflow rate.
In this application, the ultrasonic .ow sensing technology was adapted to monitor air rather than liquids. Two transducers (Blue) are used to continually send signals to each other. One signal travels with the flow (Violet), the other against (Yellow). The time difference between the two signals is used to calculate the rate of airfow within the pipe.
Supporting Efficient System Setup - AutoLearn
Simplifying the setup, installation and commissioning of high sensitivity air sampling technology was one of the key drivers behind the design of the VESDA ® LaserFOCUS. VESDA ®s AutoLearn feature supports this process by assessing environmental conditions, automatically setting acceptable smoke alarm and flow fault thresholds.
Simplifying Pipe Network Design
To simplify the application of air sampling detection the LaserFOCUS is supplied with pre-engineered pipe network designs. Designers can simply apply these proven designs to typical installations and have confidence that they will work.
Intelligent Software Support VSC and ASPIRE2
VESDA ® LaserFOCUS is supported by the next generation of VESDA ® intelligent software packages. The VESDA ® System Configurator Software (VSC) offers a high level of programming flexibility through its on-line and off-line configuration capabilities. Rapid diagnostic abilities, concurrent configuration views, and multi device smoke trending are additional features designed to simplify system design.
Complementing VSC, ASPIRE2 speeds up and simplifies the design of new and more complex pipe network layouts. Key features such as design wizards, isometric views, an automated design verification process, and improved AutoBalance capabilities ensure that a tailored pipe layout is easy to achieve.
Both VSC and ASPIRE2 are backwards compatible with the VESDA ® Laser-based detector family.